48 research outputs found
Mapping Exoplanets
The varied surfaces and atmospheres of planets make them interesting places
to live, explore, and study from afar. Unfortunately, the great distance to
exoplanets makes it impossible to resolve their disk with current or near-term
technology. It is still possible, however, to deduce spatial inhomogeneities in
exoplanets provided that different regions are visible at different
times---this can be due to rotation, orbital motion, and occultations by a
star, planet, or moon. Astronomers have so far constructed maps of thermal
emission and albedo for short period giant planets. These maps constrain
atmospheric dynamics and cloud patterns in exotic atmospheres. In the future,
exo-cartography could yield surface maps of terrestrial planets, hinting at the
geophysical and geochemical processes that shape them.Comment: Updated chapter for Handbook of Exoplanets, eds. Deeg & Belmonte. 17
pages, including 6 figures and 4 pages of reference
A programme of studies including assessment of diagnostic accuracy of school hearing screening tests and a cost-effectiveness model of school entry hearing screening programmes
Background
Identification of permanent hearing impairment at the earliest possible age is crucial to maximise the development of speech and language. Universal newborn hearing screening identifies the majority of the 1 in 1000 children born with a hearing impairment, but later onset can occur at any time and there is no optimum time for further screening. A universal but non-standardised school entry screening (SES) programme is in place in many parts of the UK but its value is questioned.
Objectives
To evaluate the diagnostic accuracy of hearing screening tests and the cost-effectiveness of the SES programme in the UK.
Design
Systematic review, case–control diagnostic accuracy study, comparison of routinely collected data for services with and without a SES programme, parental questionnaires, observation of practical implementation and cost-effectiveness modelling.
Setting
Second- and third-tier audiology services; community.
Participants
Children aged 4–6 years and their parents.
Main outcome measures
Diagnostic accuracy of two hearing screening devices, referral rate and source, yield, age at referral and cost per quality-adjusted life-year.
Results
The review of diagnostic accuracy studies concluded that research to date demonstrates marked variability in the design, methodological quality and results. The pure-tone screen (PTS) (Amplivox, Eynsham, UK) and HearCheck (HC) screener (Siemens, Frimley, UK) devices had high sensitivity (PTS ≥ 89%, HC ≥ 83%) and specificity (PTS ≥ 78%, HC ≥ 83%) for identifying hearing impairment. The rate of referral for hearing problems was 36% lower with SES (Nottingham) relative to no SES (Cambridge) [rate ratio 0.64, 95% confidence interval (CI) 0.59 to 0.69; p < 0.001]. The yield of confirmed cases did not differ between areas with and without SES (rate ratio 0.82, 95% CI 0.63 to 1.06; p = 0.12). The mean age of referral did not differ between areas with and without SES for all referrals but children with confirmed hearing impairment were older at referral in the site with SES (mean age difference 0.47 years, 95% CI 0.24 to 0.70 years; p < 0.001). Parental responses revealed that the consequences to the family of the referral process are minor. A SES programme is unlikely to be cost-effective and, using base-case assumptions, is dominated by a no screening strategy. A SES programme could be cost-effective if there are fewer referrals associated with SES programmes or if referrals occur more quickly with SES programmes.
Conclusions
A SES programme using the PTS or HC screener is unlikely to be effective in increasing the identified number of cases with hearing impairment and lowering the average age at identification and is therefore unlikely to represent good value for money. This finding is, however, critically dependent on the results of the observational study comparing Nottingham and Cambridge, which has limitations. The following are suggested: systematic reviews of the accuracy of devices used to measure hearing at school entry; characterisation and measurement of the cost-effectiveness of different approaches to the ad-hoc referral system; examination of programme specificity as opposed to test specificity; further observational comparative studies of different programmes; and opportunistic trials of withdrawal of SES programmes
Recommended from our members
Gaze-grasp coordination in obstacle avoidance: differences between binocular and monocular viewing
Most adults can skillfully avoid potential obstacles when acting in everyday cluttered scenes. We examined how gaze and hand movements are normally coordinated for obstacle avoidance and whether these are altered when binocular depth information is unavailable. Visual fixations and hand movement kinematics were simultaneously recorded, while 13 right-handed subjects reached-to-precision grasp a cylindrical household object presented alone or with a potential obstacle (wine glass) located to its left (thumb's grasp side), right or just behind it (both closer to the finger's grasp side) using binocular or monocular vision. Gaze and hand movement strategies differed significantly by view and obstacle location. With binocular vision, initial fixations were near the target's centre of mass (COM) around the time of hand movement onset, but usually shifted to end just above the thumb's grasp site at initial object contact, this mainly being made by the thumb, consistent with selecting this digit for guiding the grasp. This strategy was associated with faster binocular hand movements and improved end-point grip precision across all trials than with monocular viewing, during which subjects usually continued to fixate the target closer to its COM despite a similar prevalence of thumb-first contacts. While subjects looked directly at the obstacle at each location on a minority of trials and their overall fixations on the target were somewhat biased towards the grasp side nearest to it, these gaze behaviours were particularly marked on monocular vision-obstacle behind trials which also commonly ended in finger-first contact. Subjects avoided colliding with the wine glass under both views when on the right (finger side) of the workspace by producing slower and straighter reaches, with this and the behind obstacle location also resulting in 'safer' (i.e. narrower) peak grip apertures and longer deceleration times than when the goal object was alone or the obstacle was on its thumb side. But monocular reach paths were more variable and deceleration times were selectively prolonged on finger-side and behind obstacle trials, with this latter condition further resulting in selectively increased grip closure times and corrections. Binocular vision thus provided added advantages for collision avoidance, known to require intact dorsal cortical stream processing mechanisms, particularly when the target of the grasp and potential obstacle to it were fairly closely separated in depth. Different accounts of the altered monocular gaze behaviour converged on the conclusion that additional perceptual and/or attentional resources are likely engaged compared to when continuous binocular depth information is available. Implications for people lacking binocular stereopsis are briefly considered
Multi-messenger observations of a binary neutron star merger
On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta
Oral l-menthol reduces thermal sensation, increases work-rate and extends time to exhaustion, in the heat at a fixed rating of perceived exertion
PurposeThe study investigated the effect of a non-thermal cooling agent, l-menthol, on exercise at a fixed subjective rating of perceived exertion (RPE) in a hot environment.MethodEight male participants completed two trials at an exercise intensity between ‘hard’ and ‘very hard’, equating to 16 on the RPE scale at ~35 °C. Participants were instructed to continually adjust their power output to maintain an RPE of 16 throughout the exercise trial, stopping once power output had fallen by 30%. In a randomized crossover design, either l-menthol or placebo mouthwash was administered prior to exercise and at 10 min intervals. Power output, VO2, heart rate, core and skin temperature was monitored, alongside thermal sensation and thermal comfort. Isokinetic peak power sprints were conducted prior to and immediately after the fixed RPE trial.ResultsExercise time was greater (23:23 ± 3:36 vs. 21:44 ± 2:32 min; P = 0.049) and average power output increased (173 ± 24 vs. 167 ± 24 W; P = 0.044) in the l-menthol condition. Peak isokinetic sprint power declined from pre-post trial in the l-menthol l (9.0%; P = 0.015) but not in the placebo condition (3.4%; P = 0.275). Thermal sensation was lower in the l-menthol condition (P = 0.036), despite no changes in skin or core temperature (P > 0.05).Conclusion These results indicate that a non-thermal cooling mouth rinse lowered thermal sensation, resulting in an elevated work rate, which extended exercise time in the heat at a fixed RPE